Ws sup720 3b supported line cards. The other model has 6500-E chassis , FWSM and Sup 720 . Ws sup720 3b supported line cards

 
 The other model has 6500-E chassis , FWSM and Sup 720 Ws sup720 3b supported line cards -Installation for new Sup 2T

122-18. cisco WS-C6509-E (R7000) processor (revision 1. 5 MSFC3 Daughterboard WS-SUP720 SAL1228WJ5H 3. Mod Online Diag Status---- ----- 1 Minor Error 2 24 CEF720 24 port 1000mb SFP WS-X6724-SFP SAL0AAAAAAA. Actions performed: 1) Reboot 2) Re-seat the module. 07-15-2011 12:54 AM. Buy brand new Cisco 6500/7600 module, fast shipping to the worldwide. WS-X6724-SFP= Catalyst 6500 24-port GigE Mod: fabric-enabled (Req. Mod Online Diag Status---- -----2 Pass 3 Not Applicable. WS-F6K-DFC= Dist Fwd Card for 65xx, 6816 Modules used with SUP2 See the Product Migration Options section below for detailed information on replacing this product. It will handle all the control-plane and management plane. VS-S2T-10G . We are using SS. 1 Ok. 2(33)SRB4?. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. 5 Ok. Catalyst 6500/Cisco 7600 Supervisor 720 Fabric MSFC3 PFC3BXL . The cards provide the features supported in the selected operating mode (even if a card has a higher version number). The WS-F6K-DFC is only supported on the sup2. The memory can be upgraded to 1 GB. Mod Online Diag Status---- ----- 1 Minor ErrorCisco announces the end-of-sale and end-of-life dates for the Cisco Catalyst 6500 Series Supervisor Engine 720-10G-3C, Select 67xx Line Cards, and Accessories. I attached another picture. If a line card with DFC3B is inserted into a switch with SUP720-3BXL, the line card does not power up. This two cards installed in cat6509E. Router#. 2(17d)SXB1. S2TIBK9-15201SY IOS IP Base. (we know they only do 40G into. ) It's better to consider upgrading the 6500 to something more recent. 16 port dCEF256 Gigabit Ethernet interface module for the Cisco Catalyst 6500 Series switches with dual fabric channel interfaces and. Sup720-PFC3b with WS-X6748-GE-TX (CFC) line cards and a WS-X6516A-GBIC blade (where the SVI for my LDP neighbor ultimately goes), or just at port level? Trying to take back my sanity and collapse some multi-site vrf-lite, but want to make sure I have all my ducks in a row. 1Q standard. My customer supervisor is sup720-3B and he told me that a CiscoIf you configure Cisco 6509 switch with Sup720-3B with WS-X6816-GBIC and. Policy Feature Card 3BXL (PFC3BXL) Supported only with Supervisor Engine 720. There are three flavors, PFC3A, PFC3B and PFC3BXL, correspond to WS-SUP720, WS-SUP720-3B and WS-SUP720-3BXL. Product Code WS-SUP720-3B= WS-SUP720. Anyone seen this or experienced this before. Table A-3 lists the supported combinations of WS-F6K-DFC3 daughter cards with the Supervisor Engine 720 models and the corresponding functionality levels. The 6708 will not work with a sup2T (and probably not a. Mod Ports Card Type Model . Supervisor Engine 720 (WS-SUP720-3BXL) is shipped with a factory-installed PFC3BXL daughter card (WS-F6K-PFC3BXL) and a factory-installed MSFC3 daughter card (WS-F6K-MSFC3). The Supervisor Engine 720 family is supported on both operating systems–Cisco Catalyst OSRelease 15. Issue the hw-module uplink select. Description. If you configure Cisco 6509 switch with Sup720-3B with WS-X6816-GBIC and. Jun 27, 2012, 3:48 PM Post #1 of 27 (16773 views) Permalink. Aside from that, the VS-S720-10G has a radically different architecture than the WS-SUP720-3B. 6 16 SFM-capable 16 port 10/100/1000mb RJ45 WS-X6516-GE-TX. 2(14)SX: WS-SUP720-3B: PFC3B with 512MB DRAM MSFC3 WITH 512 MB DRAM and 64MB bootflash: 12. WS-SUP720-3B. Had the existing configuration config saved in a txt file and replaced the supervisor. NAME: "2", DESCR:. 5(1), IOS 12. 7 Centralized Forwarding Card WS-F6700-CFC SAL1611704A 4. 1 (3): 5 2 Supervisor Engine 720 (Active) WS-SUP720-3B SAL1002A4BQ. Distributed Forwarding Card-3B. Customers Also Viewed These Support Documents. All other authorized pick up people MUST ring the doorbell/phone. 2(14)sx ws-5486 12. We have a few 6509's w/ WS-SUP720-3B sup engines, that will need to be replaced because of their EoX status. If you don't need any new special features, maybe SRE5 is a better choose, you know the 15. WS-SUP720-3B Export Bookmark Overview Datasheet Parametric Crosses Overview Familiarize yourself with the fundamental general information, properties, and. 6 Policy Feature Card 3 WS-F6K-PFC3B SAL1424KF0R 2. The Supervisor Engine 720 family is supported on. Each family may have 2 access cards. It goes out the port of the same card/slot with DSCP 0. 1. WS-X6548-GE-TX. Note The Ethernet Services 20G line cards support all Cisco 7600 series routers except for the Cisco 7603 router. 4 Distributed Forwarding Card WS-F6700-DFC3C SAL1222SCMD 1. started booting in a loop with these messages: Aug 16 15:54:08 MDT: %PFREDUN-SP-6-ACTIVE: Standby initializing for SSO mode. Supervisor Module 720----WS-SUP720-3B. (enabling 4-port 10GE and 48-port 10/100/1000 density line cards). 65. Because there are switch processor (SP) and route processor (RP) memory on the Supervisor Engine 720. 1Q2T shared between 8 ports. The system had a primary and backup supervisor card (SUP720) running in SSO. 5 2 Supervisor Engine 720 (Active) WS-SUP720-3BNo recent hardware/software changes have been made. Is WS-SUP720-BASE supported in 6509-E chassis? clayhawks. Interface Cards ; WS-SUP720-3B Catalyst 6500/Cisco 7600 Supervisor Engine Management Module (WS-SUP720-3B=) Zoom the image with the mouse . Options. 1 x 6509 with SUP720-3B running IOS 12. WS-SUP720-3B • Two Gigabit Ethernet uplink ports: port 1 supports a 1-Gbps SFP module; port 2 is configurable with either a 1-Gbps SFP module or a 10/100/1000-Mbps RJ-45 connector • Integrated 720-Gbps switch fabricThanks for pointing this out. Table A-3 lists the supported combinations of WS-F6K-DFC3 daughter cards with the Supervisor. 3 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE SAXXXXXXXXX. 0 Ok 5 Policy Feature Card 3 WS-F6K-PFC3B SAL16127XRF 2. HTH, Mark. WS-CF-UPG= (sup-bootdisk:). 0 Ok 6 Policy Feature Card 3 WS-F6K-PFC3BXL SAL1339ZEE9 1. View 2 Replies View Related Cisco Switching/Routing :: Are WS-X6148-GE-TX / WS-X6148A-GE-TX Compatible With WS-X6K-SUP1A-2GE Mar 17, 2013. XFP modules supported in SPA-1X10GE-L-V2 on SIP-400. 06-21-2016 06:36 PM. meanwhile i have formatted a compact flash in the one that are working fine cop. Failed to bring online because of registration timer event. These channels can run at 8Gbps or 20Gbps depending upon the line card used. Standby has 458752K/65536K bytes of memory. 3 Other. View and Download Cisco WS-SUP720-3B - Supervisor Engine 720 user manual online. 5 Policy Feature Card 3 WS-F6K-PFC3B SAL1225UDJ0 2. Only Sup720 with VSSO have the traffic meter support. rommon 5> reset. -Load the Default IOS of SUP-T2. 8 Ok > 5 MSFC3 Daughterboard WS-SUP720 SAL1101CZST 2. The. The Cisco Catalyst 6500/Cisco 7600 Series Supervisor Engine 720-3 BXL is a family of Supervisor Engine (s) designed to deliver scalable performance and rich set of IP features in hardware. 0 % Inventory Accuracy. -Power on Chasis. We will be upgrading the following switches. Mod MAC addresses Hw Fw Sw Status. AC and DC power supply. Can these modules work with WS-SUP720-3B and new line card WS-X6724-SFP? Best Regards,Currently, I can not use MTU command on X6148 but can on X6148A. However, when i check the buffer & Queue spec. 5 12. Sup720/3B/3BXL 10-28-2020 10:02 AM. WS-SUP720-3BXL . 2(17b)SXB and later Protocols Layer 3 routing protocols, Border Gateway Protocol version 4 (BGPv4), Open ShortestCisco WS-SUP720-3B - Supervisor Engine 720 Pdf User Manuals. 2(17d)SXB1 : WS-SUP720-3BXL:cisco WS-C6509-E (R7000) processor (revision 1. a981. I have a customer with a SUP720-3b that works fine on its own, but when another SUP720-3b is inserted into the chassis we get the following feedback. I have no problem with classic cards like WS-X6416-GBIC (16 port fiber module). 4 PwrDown. This concerns only line cards. Now it will no ignore the config when it boots. ) I have WS-SUP720-3B and compact flash. The CAT6509 in question has WS-C6509 chassis, WS-SUP720-BASE sup engine, running in hybrid mode (CATOS 8. 1-2 . PARENT/GUARDIAN #2 Surname First Name Address same as child. Note: WS-F6700-DFC3B/3BXL and WS-F6700-DFC3C/3CXL are used only on CEF720 or WS-67xx series line cards WS-F6K-DFC3A(=),WS-F6K-DFC3B(=),WS-F6K-DFC3BXL(=) are. 1P2Q2T shared between 8 ports. 2 Okparts >> refurbished parts refurbished parts - ws-sup720-3b= - catalyst 6500-cisco 7600 - supervisor 720 s-n:sal12437r6a - computer networking equipm: china: india: 1: 85176290:. 122-33. 6 Ok. Supervisor Engine-Modulen und Line Cards. Hi everybody. The VSS mode is currently supported in PFC3C or PFC3CXL only, and is. UPC - 746320914848. 6500, 6000, 5500, 5000, 4500 및 4000 Series와 같은 모듈형 Cisco Catalyst 스위치는 모든 모듈 (전원 공급 장치, 팬 트레이, 수퍼바이저 모듈 및 기타 라인 및 서비스 모듈)의 OIR (Online Insertion and Removal) 또는 핫 스왑 기능을. 48 secs (2432 bytes/sec) sup720# sup720#configure terminal Enter configuration commands, one per line. 5. Chinese; EN US; French; Japanese; Korean; Portuguese; Log In03-22-2007 06:30 AM. 1. cisco WS-C6509 (R7000) processor (revision 3. Slot Card-Type Watts A @42V Watts A @42V State StatePage 36 Modular Switches: Cisco Catalyst 6500 Series Supervisor Engines Hardware Features Virtual Switching Supervisor SUP 720 SUP 32 SUP 32-PISA 720-10G VS-S720-10G-3CXL WS-SUP720-3BXL WS-SUP32-10GE-3B WS-SUP32-10GE-PISA VS-S720-10G-3C WS-SUP720-3B WS-SUP32-GE-3B WS-SUP32-GE-PISA Chassis Supported. Labels: Labels:. 1 Ok 5 MSFC3 Daughterboard WS-SUP720 SAD092607JG 2. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Series Supervisor Engine 720-10G-3C, Select 67xx Line Cards, and Accessories 06/Jan/2015. I understand the WS-F6700-CFC card is required for each of those line cards to support this. Cat 6500 Supervisor 32 with 2 ports 10GbE and PFC3B . The memory can be upgraded to 1 GB. . 7 Centralized Forwarding Card WS-F6700-CFC 2. If the line card supports it, you probably want a WS-F6700-DFC3B. If you reach this limit, the switch does not allow further vty sessions. The BC Services Card Help Desk is open Monday to Friday (except statutory holidays) from 7:30 am to 5 pm Pacific Standard Time, or 8:30 am to 6 pm. WS-X6148-FE-SFP will require WS-SUP720-3B or VS-S720-10G-3C; WS-X6148-FE-SFP= will require WS-SUP720-3B or VS-S720-10G-3C Customers may be able to use the Cisco Technology Migration Program (TMP) where applicable to trade-in eligible products and receive credit toward the purchase of new Cisco equipment. com, a global distributor of electronics components. Quick Links. (WS-SUP720-3B and WS-SUP720-3BXL), and the new Cisco Route Switch Processor 720 (RSP720-3C and RSP720-3CXL) The Cisco 7613 incorporates many. Regards. You need a DFC3 to work with the sup720. . 2 (17d)SXB Other. Supervisor Engine 720 제품군은 Cisco Catalyst OS® 및 Cisco IOS® 운영 체제 모두에서 지원됩니다. 5 Ok. The last day to order the affected product(s) is February 11, 2013. 06-09-2013 07:19 PM. rommon 4> sync. Up to 1024 VRFs with a total of up to 256,000 routes per system. 0. The sup720 supports classic bus line cards and both (old) CEF256 and (new) CEF720 fabric line cards. According to logs my VLS link went down and one of switch has rebooted. 7 Ok > 5 Policy Feature Card 3 WS-F6K-PFC3BXL SAL1102DGJY 1. 1 Ok 5 Policy Feature Card 3 WS-F6K-PFC3B SAL1028UJ5L 2. Laurent. (BTW, the sup32's supervisor ports, were designed for high performance as uplinks. Step 2 Shut down the switch. Manufacturer Part#: Cisco WS-SUP720-3BXL WS-SUP720-3BXL Interface & Line Card WS-SUP720-3BXL - Cisco Catalyst 6500/Cisco 7600 Series Supervisor Engine 720 is a family of Supervisor Engine(s) designed to deliver scalable performance and rich set of IP features in hardware. Cisco Catalyst 6500 | Sup720-3B Flash Upgrade. Views. WS-X6K-S2-MSFC2= Catalyst 6500 Supervisor Engine 2, 2GE, plus MSFC-2/PFC-2, Spare . Table 1-6 POS Line Card and Module Support by Release Line Card or Module Cisco IOS Release 12. Supervisor Engine 2 (WS-X6K-S2-PFC2) is shipped with a factory-installed PFC2 daughter card (WS-F6K-PFC2); there is no MSFC daughter card installed. hi, I've 2 x 6509-E chassis. 소개. I already purchased a FAN tray, two power units and 3 line cards (2x mini GBICs, 1x RJ54 ports). Yes, they could support 68xx and 69xx and spin new ES cards (ES++), but that would be fairly expensive. Si vous avez un Supervisor Engine. 3 Ok. Cisco has announced the EoS for the entire line of the 6500: From supervisor cards to line cards and chassis. Giá khuyến mại Vui lòng gọi. If I use SUP-720-3B and WS-X6724-SFP(CFC), 6724. 6 2 Supervisor Engine 720 (Active) WS-SUP720-3B SAL1514ARJS. I have a SUP720-3BXL that will not boot. 5 MSFC3 Daughterboard WS-SUP720 SAL1020NMFZ 2. 3 Ok 5 MSFC3 Daughterboard WS-SUP720 SAD094608X1 2. Buy or Renew. I also found this from Cisco's MPLS for Beginners: Q. 05-30-2018 01:19 PM. "Catalyst 6500 512MB DRAM on the MSFC2 or SUP720. 3AF inline power. Laurent. Which brings up another question for me: Can you use any of the DFC3s (WS-F6700-DFC3B, WS-F6700. 3 Ok. WS-SUP720-3B=*18 WS-SUP720-3BXL*18-VS-S720-10G-3C*19 VS-S2T-10G C6800-SUP6T= VS-S720-10G-3CXL*19-Legacy. Cisco WS-SUP720-3B Catalyst Supervisor 720 Module With Integrated Fabric Switch Full Working Order,. rommon 6 > dir slot0: >>> Beliving that you have image on the slot0 ( (the device ID is slot0: and/or slot1:, corresponding to the PCMCIA cards inserted in the respective slots): 6 2 Supervisor Engine 720 (Hot) WS-SUP720-3B SAL11477L4J The device is operating so we'are creating low impact towards the environment. Table 1-6 lists the POS line card and module support for each release. Solved: Hi, We have WS-X6348-RJ-45, WS-X6324-100FX-MM, WS-X6408A-GBIC and WS-X6816-GBIC ( with daughter card WS-F6K-DFC ). Using. Having some compatability issues with a CAT6509 and some specific new line cards. What happens if line cards with different PFC modes are inserted in a Virtual Switching System (VSS) with PFC3C? A. The last day to order the affected product(s) is July 31, 2015. Redundant Supervisor Engines must be of the same type with the same model feature card to support redundancy. 1-Sy7(MD) (What will be the upgrade path and how many time chassis will be a reboot in this process). rommon 2> IP_SUBNET_MASK=<subnet mask for the above IP>. . Asus Video ; ATI Video Cards; EVGA Video Cards; Nvidia Video Cards; PNY Video Cards; Power Supplies. This CF adaptor-SP comes with more memory size than the older Flash. 2 MB shared between 8 ports. P/S) VS-C6509E-S720-10G Catalyst Chassis+Fan Tray+Sup720-10G; IP Base ONLY incl. 2(18)SXD7b. WS-SUP720-3B WS-SUP720 . Current bootup diagnostic level: minimal 3 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE SAXXXXXXXXX. If you configure Cisco 6509 switch with Sup720-3B with WS-X6816-GBIC and. Technology and Support; Networking; Routing; 6509 WS-SUP720-3BXL switch fabric; Options. Table 1-5 ATM Line Card and Module Support by Release Line Card or Module Cisco IOS Release 12. 000 packets or even less in Tengigabit interfaces, it starts to increase cpu usage and it is freezed in 10 seconds, more or less. About three weeks ago, Cisco IOS 15. 122-18. Sup-bootflash refers to the internal flash memory which is. The Policy Feature Card 1 (PFC1) or PFC3-equipped Supervisor Engine has a 256 unique HSRP group ID limit. SXJ2. 7 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE . On 6500/7600 platform, the SUP card also support physically the fabric who handles the data-plane. Supervisor Engine 720 제품군은 Cisco Catalyst OS® 및 Cisco IOS® 운영 체제 모두에서 지원됩니다. 2 (1)SY does not support these modules: Supervisor Engine 720-10GE and Supervisor Engine 720. 1 (1)SY on both active and backup supervisor modules. With a Supervisor Engine 720 and a DFC3 installed, WS-X6516-GBIC hardware revisions 5. 3 Centralized Forwarding Card WS-F6700-CFC SAL1425KQGX 4. bin. If they rebrand the Sup2T as RSP2T, they would have close to no supported line cards (only 67xx without DFCs) and, specifically, all of the high-functionality line cards (ES+) wouldn't be supported. Table 1. WS-X6724-SFP. >You need a DFC3 to work with the sup720. 30 description GESTION encapsulation dot1Q 30 xconnect 10. WS-X45-SUP6-E*5 WS-X45-SUP8-E / WS-X45-SUP9-E Table 3. 3 Ok. 6 MSFC3 Daughterboard WS-SUP720 SAL114671L0 3. WS-SUP720-3B or WS-SUP720 . Supported Cards Minimum Software Version; WS-SUP 720: PFC 3A with 512-MB DRAM MSFC3 with 512-MB DRAM and 64-MB bootflash: 12. WS-X6724-SFP= Catalyst 6500 24-port GigE. Subscribe to RSS Feed; Mark Topic as New;. SR71000 CPU at 600Mhz, Implementation 0x504, Rev 1. 1Q . While Sup720 with 3A shipped with ASSO and do not have traffic meter support. Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4 - S-65-S720 . You can generally use them as edge ports, but they often will not work/perform as well as some line card ports. 10 WS-SUP720-3B does not fit into WS-C6509 Go to solution dennis. Once you got control of it, you need to change it back with "config-register 0x2102". 2 Centralized Forwarding Card WS-F6700-CFC SAL114140WX 4. x nmaxpierson at gmail. I have installed a X6704 4 port 10Gb card in slot 1 and powered up the system. Yes, these supervisor cards will work on the current chassis you've got. 248. 5 2 Supervisor Engine 720 (Active) WS-SUP720-3B . WS-SUP720-3B supports Cisco IOS 12. The chassis recognizes the new line card but doesn't boot it up. Media Type Supported: Twisted Pair: Ethernet Technology: Gigabit Ethernet: Network Technology:. *The daughter card memory exposure is soldered memory; therefore, only the daughter card must be replaced in order to address exposure issues. Its hardware-based feature set enables applications such as traditional IP forwarding, Layer 2 and Layer 3 Multiprotocol Label Switching (MPLS) VPNs. I bought a WS-C6509 chassis for a trainee and test lab, it was manufactured in 1999. 3B and 3BXL by default are shipping with VSSO. Cisco 7600 series routers support 4096 VLANs in accordance with the IEEE 802. So, to reitterate for my own clarification, the X6700-GE-TX with CFC is 100% compatible with the SUP-2T running. I have been looking everywhere for some info on the proper steps for doing this, however I have come up empty handed. Yes and no. Hi, we are using 12. If you configure Cisco 6509 switch with Sup720-3B with WS-X6816-GBIC and. 5 Policy Feature Card 3 WS-F6K-PFC3B SAL1129UTS4 2. The amount of memory on both the routing engine and the Supervisor Engine module. The WS-SUP720-3B also delivers a high switching capacity (40 Gbps per slot) which enables the 4-port 10GE and 48-port 10/100/1000 density line card. X. 03-09-2011 02:46 AM. Which brings up another question for me: Can you use any of the DFC3s (WS-F6700-DFC3B, WS-F6700. The 3B TCAM cannot handle that many IPv4 routes in hardware, causing the box to send anything above (192K) to the CPU. I will appreciate any help. 5(1), IOS 12. Quick Links Contacts;. 1 Ok. Wrong config-registry settings. 5 Ok 9 Centralized Forwarding Card WS-F6700-CFC SAXXXXXXXXX 2. and PFC3BXL, correspond to WS-SUP720, WS-SUP720-3B and WS-SUP720-3BXL. WS-SUP720-3B Cisco Catalyst 6500/7600 Supervisor Engine 720 Control Processor Fabric MSFC3 PFC3B. Chinese; EN US; French; Japanese; Korean; PortugueseI am facing a problem with a cisco 6509 SUP720-3B that goes into rommon every time i restart. 7 Centralized Forwarding Card WS-F6700-CFC SALxx 2. (If not yet announced, then it will be shortly. 6 Ok. Subscribe to RSS Feed; Mark Topic as New;The "XL" will allow you up to 1 million IPv4 routes. 57 A at 42 VDC . 1 Ok 7 MSFC3 Daughterboard WS-SUP720 SAXXXXXXXXX 2. Participant. pid: ws-sup720 , vid: , sn: sad0742033f NAME: "WS-F6K-PFC3A Policy Feature Card 3 sub-module of 5", DESCR: "WS-F6K-PFC3A Policy Feature Card 3 Rev. VS-S720-10G-3CXL, WS-Sup720, WS-Sup720-3B, and WS-Sup720-3BXL. Pages in total: 7. 5 2 Supervisor Engine 720 (Active) WS-SUP720-3B SAXXXXXXXXX. 5 MSFC3 Daughterboard WS-SUP720 SALxx 3. Which brings up another question for me: Can you use any of the DFC3s (WS-F6700-DFC3B, WS-F6700. 7 Centralized Forwarding Card WS-F6700-CFC 2. Distributed Forwarding Cards Supported with Supervisor Engine 2T. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center. When mixing DFCs in the same. It will handle all the control-plane and management plane. Many thanks John Thanks for the reply and useful info. . 0. 2) with 458720K/65536K bytes of memory. Supervisor Engine 720 (WS-SUP720-3BXL) is shipped with a factory-installed PFC3BXL daughter card (WS-F6K-PFC3BXL) and a factory-installed MSFC3 daughter card (WS-F6K-MSFC3). WS-SUP720 WS-SUP32-8GE-3B WS-SUP32-10GE-3B WS-X6724-SFP WS-X6748-SFP. 6:. WS-SUP720-3B: CATALYST 6500 / CISCO 7600 SUPERVISOR 720 FABRIC MSFC3 PFC3B:. I need to test a 1GB (RP and SP) RAM IOS in order to see if a bug disappear but i only have the memory for one supervisor. Is these modules will work with c6509E and these supervisor (VS-S720-10G-3C or VS-S720-10G-3CXL) Yes and no. The WS-F6K-DFC is only supported on the sup2. 3 do not power up. 8 Distributed Forwarding Card WS-F6700-DFC3B SAL11456G87 4. Catalyst 6500/Cisco 7600 Supervisor Engine 720 Fabric MSFC3 PFC3B (WS-SUP720-3B) Cisco CAT6000-SUP720 IOS IP W/SSH/3DES (S733ZK9-12217SXB) Additional Information: RS-232 Console Port. SXJ7. A Chairde, Have a 7609 with a WS-SUP720-3BXL Supervisor Engine, and need to buy another chassis (7606) to increase capacity , and put some reliability into our network, if either chassis/SUP Card blow, we can change cards to other chassis. New return-to-work requirements for employers and workers starting January 1, 2024. 1. Note: Cisco Catalyst Supervisor Engine WS-SUP720-3B does not support VSS. 2SR OL-10362-04 Supported Hardware Supervisor Engine 720 with PFC3B Supervisor Engine 32 Note Supervisor Engine 32 does not support this hardware: • WS-SUP720-3B • WS-F6K-PFC3BXL—Policy Feature Card 3BXL (PFC3BXL)WS-X6704-10G is Line Card with 4x 10GE port. 9 Distributed Forwarding Card WS-F6700-DFC3B SAL11456G7K 4. Each chassis has the follow modules: slot1: WS-X6724-SFP slot5: WS-Sup720-3B I would like to create a dot1q etherchannel bundle btw the two chassis using the Sup720-3B & line cards. i tried these commands: rommon 1 > IP_ADDRESS=<ip address of router interface>. For complete information, see the Cisco IOS Master Command List publication. You will not be able to "buy new cards" because line cards supported by Sup720 are long end-of-support. SXF6. However, when disconnected from power and powered back on, it is un. Additionally, the PFC version on the VS-S720 would have to fall back to PFC-3B to interface with the Sup720. WS-SUP32-GE-3B SAD084401JD 6 9 Supervisor Engine 32 8GE (Hot) WS-SUP32-GE-3B SAD084401GG !--- The active. 8 Ok > 5 MSFC3 Daughterboard WS-SUP720 SAL1101CZST 2. Buy or Renew. There was one failure message about unnsupported command but didnt take further notice. . bin and s72033-adventerprisek9_wan-mz. rommon 4> sync. Cisco Catalyst WS-SUP720-3B Supervisor Engine Module Repair Service Center. 2SXF is the last release in which the Sup720 with PFC3A is supported. 6 MSFC3 Daughterboard WS-SUP720 SAL1424KCMQ 4. Router#show sup. 6 Ok 5 MSFC3 Daughterboard WS-SUP720 SAL1645RKPG 5. The Supervisor Engine 720 family is supported on both operating systems-Cisco Catalyst OS ® and Cisco IOS ®. One question I have, I have to decide whether to buy a WS. The result of this design is more efficient use. It was very helpful. You need a DFC3 to work with the sup720. 6 OkGraphic Cards. Power cycle the SUP720. Router>en password: But above contents appeared. The Cisco Catalyst 6500/Cisco 7600 Series Supervisor Engine 720 is a family of Supervisor Engine (s) designed to deliver scalable performance and rich set of IP features in hardware. GigabitEthernet3/1 is up (if_number 272) Corresponding hwidb fast_if_number 272. 2 or higher.